Page 28 - 美国_迪创_Det-Tronics_火焰探测器_X3301_气体检测仪_PIRECL_EQP控制器_产品样本_参数表
P. 28
FANCYIND
FANCYIND
FANCYIND
SPECIFICATION DATA
FANCYIND FANCYIND UV Flame Detector
FANCYIND
X2200
DESCRIPTION HIGHLIGHTS
The X2200 UV Flame Detector meets the most ▲ ▲ Complies with FM 3260
Y E A R stringent requirements worldwide with advanced ▲ ▲ EN54 certified
3 detection capabilities and immunity to extraneous ▲ ▲ ▲ ▲ Certified SIL 2 capable
sources, combined with a superior mechanical
ATEX Directive compliant
design. The detector is equipped with both
FANCYIND
FANCYIND WARRANTY automatic and manual oi test capability. The ▲ ▲ ▲ ▲ ▲ ▲ EQP models available FANCYIND
Advanced signal processing
detector has Division and Zone explosion-proof
ratings and is suitable for use in indoor and
Arc — unequaled false alarm rejection
outdoor applications.
HART models available
▲ ▲
Responds to a fire in the presence of modulated blackbody
▲ ▲
The standard output configuration includes fire, fault and auxiliary radiation (i.e. heaters, ovens, turbines) without false alarm
relays. An optional 0 to 20 mA output with HART can be provided
in addition to the three relays. A model with pulse output is ▲ ▲ High speed capability
®
available for easy retrofitting into existing Det-Tronics controller ▲ ▲ Automatic, manual or magnetic oi (optical integrity) testing —
based systems. Auxiliary relay and 0 to 20 mA output are not no external test lamp required
available with the pulse model. A tri-color LED on the detector ▲ ▲ Easily replaceable oi plate
faceplate indicates normal condition and notifies personnel of fire ▲ ▲ Fire, fault and auxiliary relays standard
alarm or fault conditions. ▲ ▲ MODBUS RS-485 communication
▲ ▲ 0 to 20 mA isolated output (optional)
The X2200 housing is available in aluminum or stainless steel,
with NEMA 4X and IP66/IP67 rating. ▲ ▲ Pulse output for compatibility with controller based systems
(optional)
A tri-color LED on the detector faceplate indicates normal
▲ ▲
Typical applications include: condition and notifies personnel of fire alarm or fault conditions
FANCYIND — Munitions FANCYIND ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ Mounting arm allows easy sighting
FANCYIND
— Hydrogen storage
Integral wiring compartment for ease of installation
— Silane storage.
Class A wiring per NFPA-72
Meets NFPA-33 response requirement for under 0.5 seconds
RFI and EMC Directive compliant
▲ ▲ (available when model selected)
▲ ▲ Built-in data logging / event monitoring
4.1 © Detector Electronics Corporation 2014 9/14 90-1157