Page 27 - 美国_迪创_Det-Tronics_火焰探测器_X3301_气体检测仪_PIRECL_EQP控制器_产品样本_参数表
P. 27

FANCYIND
 FANCYIND
                                                    SPECIFICATIONS                      FANCYIND


        Operating Voltage   24 Vdc.  Operating range is 18 to 30 Vdc.  Certification

        Power Consumption   2.1 watts @ 24 Vdc minimum.         FM            FM
                          16.5 watts @ 30 Vdc with EOL resistor installed and   APPROVED  APPROVED
                          heater on maximum.
                                                              Class I, Div. 1, Groups B, C & D (T5);      Increased Safety Model
                                FANCYIND
 FANCYIND                 Fire Alarm:   — Form C (NO and NC contacts)   Class I, Div. 2, Groups A, B, C & D (T3);   FANCYIND
                                                                                             0539
                                                                                                   II 2 G
                                                              Class II, Div. 1, Groups E, F, & G (T5);
                                                                                            FM
                                                                                                ®
                          Contacts rated 5 amperes at 30 Vdc.
                                                                                            APPROVED
        Relays
                                                                                           Ex d e IIC T5–T6 Gb

                                                              Class II, Div. 2, Groups F & G (T3);
                                                                                           DEMKO 02 ATEX 132195X
                                                              Class III.

                                                                                                  = –50°C to +60°C).
                                    — normally de-energized

                                                                                           T6 (T
                                                                                              amb
                                    — latching/non-latching.

                                                                                                  = –50°C to +75°C).
                                                              Enclosure NEMA/Type 4X.
                                                                                           T5 (T
                                                                                              amb
                                                                                           IP66.
                                    — Form A (NO contacts)
                          Fault:

                                    — normally energized
                                    — latching/non-latching.    IECEx Certificate of Conformity  Flameproof Model
                                                              IECEx ULD 06.0018X            APPROVED 0539 ®  II 2 G
                                                                                            FM
                          Auxiliary*:   — Form C (NO and NC contacts)    Ex d e IIC T5-T6 Gb         Ex d IIC T5–T6 Gb
                                    — normally energized       T6 (T amb  = –50°C to +60°C).       DEMKO 02 ATEX 132195X

                                    — latching/non-latching.   T5 (T amb  = –50°C to +75°C).     T6 (T amb  = –55°C to +60°C).

                                                               IP66.                        T5 (T amb  = –55°C to +75°C).
        Current Output*   0–20 mA, with a maximum loop resistance of 500                   IP66.
          (Optional)      ohms from 18–19.9 Vdc, 600 ohms from 20–30 Vdc.  – or –
                                                              Ex d IIC T5-T6 Gb
        Temperature Range    Operating:   –40°F to +167°F (–40°C to +75°C).  T6 (T amb  = –55°C to +60°C).
                          Storage:   –67°F to +185°F (–55°C to +85°C).  T5 (T amb  = –55°C to +75°C).
                                                              IP66.
        Humidity Range    0 to 95% relative humidity, can withstand 100%
                          condensing humidity for short periods of time.  Dimensions   Dimensions shown in inches (centimeters).
        Field of View     The X9800 has a 90 degree cone of vision with the
 FANCYIND  Warranty       Copper-free aluminum or 316 stainless steel.  (11.9)          FANCYIND
                                FANCYIND

                          highest sensitivity lying along its central axis.
                                                               4.7
                          3 years.
        Enclosure Material
                                                                                                          4.8
                                                                               10.2
        Conduit Entry Size   3/4 inch NPT or 25 mm.            B2223           (25.9)                    (12.2)
        Shipping Weight   Aluminum:       6 pounds   (2.75 kg).
          (Approximate)   Stainless Steel:  10 pounds  (4.5 kg).
                                                                                            2
                                                                                                           2
                                                              Wiring            14 AWG (2.08 mm ) or 16 AWG (1.31 mm )
                                                                                shielded cable is recommended.
        Response Characteristics
        Very High Sensitivity, TDSA On                                    9  4-20 mA +  19  4-20 mA –   SPARE  29
                            Distance   Typical Response                   8  4-20 mA + REF  18  4-20 mA – REF SPARE  28
           Fuel     Size                           Quick Fire
                            Feet (m)  Time (seconds)                      7  COM FIRE   17  COM FIRE  COM AUX  27
         n-Heptane  1 x 1 foot  85 (25.9)  15         Off                 6  N.O. FIRE  16  N.O. FIRE  N.O. AUX  26
          Methane  32 inch plume  60 (18.3)  5        Off                 5  N.C. FIRE  15  N.C. FIRE  N.C. AUX  25
          Propane   Torch    2 (0.6)     0.04         On                  4  COM FAULT  14  COM FAULT  RS-485 A  24
        NOTE:   Refer to the X9800 instruction manual 95-8554 for         3 2  N.O. FAULT  13  N.O. FAULT  RS-485 B  23
                                FANCYIND
 FANCYIND  *Auxiliary relay and 0 to 20 mA output are not available on pulse output model.  Wiring Terminal Identification for Standard X9800
                                                                                        FANCYIND
              details regarding detector response.
                                                                                                      22
                                                                                          24 VDC +
                                                                                        12
                                                                            24 VDC +
                                                                                                 MAN O i
                                                                                        11
                                                                                                      21
                                                                          1
                                                                            24 VDC –
                                                                                                 24 VDC –
                                                                                          24 VDC –
                                                                                                      B2061
        Specifications subject to change without notice.                           Detector Electronics Corporation
        Det-Tronics, the DET-TRONICS logo, and Protect•IR are registered trademarks     REGISTERED BY UL AND BSI   6901 West 110th Street • Minneapolis, Minnesota 55438 USA
        or trademarks of Detector Electronics Corporation in the United States, other   ISO 9001
        countries, or both. Other company, product, or service names may be trademarks   REGISTERED FIRM   Operator: (952) 941-5665 or (800) 765-FIRE
                                                           REGISTERED FIRM
        or service marks of others.                       NO. A2305 • NO. 25826   Customer Service: (952) 946-6491 • Fax (952) 829-8750
        ©Copyright Detector Electronics Corporation 2010. All rights reserved.  http://www.det-tronics.com • E-mail: det-tronics@det-tronics.com
   22   23   24   25   26   27   28   29   30   31   32