Page 26 - 美国_迪创_Det-Tronics_火焰探测器_X3301_气体检测仪_PIRECL_EQP控制器_产品样本_参数表
P. 26
FANCYIND
FANCYIND
FANCYIND
SPECIFICATION DATA
FANCYIND FANCYIND FANCYIND
IR Flame Detector
X9800
DESCRIPTION FEATuRES AND BENEFITS
The evolution continues with the new X9800 IR • FM 3260 (2000).
Y E A R Flame Detector. The X9800 meets the most • EN 54-10 Certified (VdS).
stringent requirements worldwide with advanced
3 detection capabilities and immunity to extraneous • ATEX Directive compliant.
• EQP models available.
sources, combined with a superior mechanical
• TDSA (Time Domain Signal Analysis) for unequaled false alarm
FANCYIND
FANCYIND WARRANTY manual and magnetic oi test capability. The • Responds to a fire in the presence of modulated blackbody
FANCYIND
design. The detector is equipped with automatic,
rejection.
detector has Division and Zone explosion-proof
radiation (i.e. heaters, ovens, turbines) without false alarm.
ratings and is suitable for use in indoor and
• HART models available.
outdoor applications.
• High speed capability — 40 milliseconds.
The standard output configuration includes fire, fault and auxiliary • Microprocessor controlled heated optics for increased
relays. An optional 0 to 20 mA output with HART can be provided resistance to moisture and ice.
in addition to the three relays. A model with pulse output is • Automatic, manual or magnetic optical integrity (oi) testing —
available for easy retrofitting into existing Det-Tronics controller no external test lamp required.
based systems. Auxiliary relay and 0 to 20 mA output are not • Easily replaceable oi plate.
available with the pulse model. A tricolor LED on the detector • Fire, fault and auxiliary relays standard.
faceplate indicates normal condition and notifies personnel of fire • MODBUS RS-485 communication.
alarm or fault conditions.
• 0 to 20 mA isolated output (optional).
The X9800 housing is available in aluminum or stainless steel, • Pulse output for compatibility with controller based systems
with NEMA 4X and IP66 rating. (optional).
• A tricolor LED on the detector faceplate indicates normal
Typical applications include: • Operates under adverse weather conditions and in dirty
condition and notifies personnel of fire alarm or fault conditions.
FANCYIND
FANCYIND — Petrochemical applications • Class A wiring per NFPA-72.FANCYIND
— Dirty environments
environments.
— Automotive applications
• Mounting swivel allows easy sighting.
— Powder coating applications
• Integral wiring compartment for ease of installation.
— Turbines.
• Meets NFPA-33 response requirement for under 0.5 second
(available when model selected).
• RFI and EMC Directive compliant.
• Built-in data logging/event monitoring.
3.2 ©Detector Electronics Corporation 2010 11/10 90-1160