                                                                                             speciFicAtion DAtA

                                                                                                  Line of Sight

                                                                Infrared Hydrocarbon Gas Detector
                                                                                               Model LS2000


 FANCYIND                       FANCYIND                                                FANCYIND




















                            Description                                     FeAtUres AnD BeneFits


            Y e A r    The Model LS2000 is a line of sight infrared   ▲ ▲ ± 0.8 degree misalignment tolerance (~±56cm @ 40m;
             5
                                                                     ~±168cm @ 120m)
                       gas detection system that provides continuous
                       monitoring of combustible hydrocarbon gas
                                                                   ▲ ▲ IR source: High performance, long lasting xenon flashlamp -
                                                                     10 year warranty on IR source
                                FANCYIND
                                                                                        FANCYIND
 FANCYIND   WArrAntY   concentrations in the range of 0 to 5 LFL-meters,   ▲ ▲ Large detection coverage area (detection range 5-120 meters)
                       over a distance of 5 to 120 meters.  Standard
                       system outputs include an electrically isolated/
                                                                   ▲ ▲ Maximum distances and proper operation verified with 95%
                                                                     signal obscuration
                       non-isolated 4-20 mA dc current output, with
           HART communication and RS-485 MODBUS communication.
                                                                   ▲ ▲ Compliance to FM6325 and ISA-12.13.04 performance standards
           Alarm and fault relays are available as an option.
                                                                   ▲ ▲ Certified SIL 2 capable
           The system consists of two stainless steel modules — a   ▲ ▲ Third party performance certified and factory calibrated to
           transmitter and a receiver, along with mounting fixture hardware.    Methane
           Both modules are powered from an external 24 volt DC supply.    ▲ ▲ Propane and Butane detection performance Det-Tronics verified
           The receiver provides the measurement signal outputs, and is   ▲ ▲ Microprocessor controlled heated optics for increased
           furnished with onboard “status indication” LEDs and an internal   resistance to moisture and ice.
           magnetic calibration switch.  The transmitter houses a high quality   ▲ ▲ Standard 4-20 mA output (configurable), HART
           xenon flash lamp.                                         communication, RS-485 Modbus
                                                                   ▲ ▲ Optional alarm relays (Ex d only)
           The LS2000 is certified explosion-proof for use in Class I,   ▲ ▲ Mounting hardware and alignment brackets included
           Division 1 and Division 2 hazardous areas, and holds third party
           performance certification for methane gas detection.  Propane   ▲ ▲ Mounts to pole (4.5” nominal OD) or flat surface
           and butane detection are also available (Det-Tronics verified).  It   ▲ ▲ Built-in locking adjusters deliver fine control of alignment angles
                                FANCYIND
 FANCYIND  facility protection system using other Det-Tronics equipment.  ▲ ▲ Multi-color LEDs are provided on both modules for detailed
                                                                                        FANCYIND
           can be used as a stand-alone detector, or as part of a larger
                                                                   ▲ ▲ Telescope is the only tool needed for optimal alignment
                                                                     visual indication of operating status.
           By connecting the transmitter and receiver via a three-wire
                                                                   ▲ ▲ Non-intrusive zero calibration options: on-board magnetic
           shielded cable, an optional “communication link” can be
                                                                     external switch
           created between the two devices to enable: single point system   switch, MODBUS communication, HART communication, or
           diagnostics, dynamic lamp power optimization, synchronized   ▲ ▲ Optional 475 field communicator unit for communication,
           LEDs, transmitter configuration via connection to the receiver, and   diagnostic, and set up from point to point
           calibration initiation from either device.              ▲ ▲ Modular design for ease of maintenance